Product Overview
|
|
Description |
APC Back-UPS CS, 350VA/210W, Input 120V/ Output 120V,
Interface Port DB-9 RS-232, USB |
|
 |
| |
Features |
Addl Surge Protected Outlets, Audible Alarms, Building
wiring fault indicator, Cord Management, Intelligent Battery
Management, Internet FAX - modem - DSL surge protection,
Overload Indicator, Replace Batt Indicator, Software,
Unattended Safe & Graceful Shutdown, USB Connectivity, User
Replaceable batteries |
|
 |
|
Includes |
CD with software, User Manual, USB cable, Velcro Cord
Management Straps |
|
 |
|
UPC Code |
731304016298 |
|
 |
 |
|
Options |
|
Optional Batteries
|
Click here to view optional
Batteries. |
|
 |
|
Optional Service |
Click here to view optional
Service. |
|
 |
 |
|
Documentation |
| |
User Manual & Installation
Guides |
APC
Safety Guide (120V)
Back-UPS
CS 350/500 (120V)
|
|
 |
 |
Communications & Management
|
|
Interface port |
DB-9 RS-232 , USB |
|
 |
|
Control panel |
LED status display with On Line : On Battery : Replace
Battery and Overload indicators |
|
 |
|
Audible alarm |
Alarm when on battery : distinctive low battery alarm :
overload continuous tone alarm |
|
 |
| |
Included Software |
APC Shutdown Manager
APC PowerChute Personal Edition
|
|
 |
 |
|
Output |
|
Output power capacity
|
350 VA |
|
 |
|
Output power capacity
|
210 Watts |
|
 |
|
Nominal output voltage
|
120 V |
|
 |
|
Waveform type |
Stepped approximation to a sinewave |
|
 |
| |
Output Connections
|
|
(3)NEMA 5-15R |
|
|
(3)NEMA 5-15R (Surge) |
|
|
|
 |
 |
Input
|
|
Nominal input voltage
|
120 V |
|
 |
|
Input frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
|
 |
| |
Input Connection Type
|
| NEMA
5-15P |
|
|
|
 |
|
Cord Length |
6 feet (1.83 meters ) |
|
 |
|
Input voltage range for main
operations |
98 - 140 V |
|
 |
 |
Surge Protection and Filtering
|
|
Surge energy rating
|
480 joules |
|
 |
| |
Filtering |
Full time multi-pole noise filtering : 5% IEEE surge
let-through : zero clamping response time : meets UL 1449 |
|
 |
|
Dataline protection
|
RJ-45 Modem/Fax protection (two wire single line) |
|
 |
 |
|
Runtime |
| |
Typical backup time
at half load |
18.1 minutes (105 Watts) |
|
 |
| |
Typical backup time
at full load |
4.7 minutes (210 Watts) |
|
|
 |
|
Batteries |
|
Battery type |
Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof |
|
 |
|
Typical recharge time
** |
8 hour(s) |
|
 |
|
Replacement battery cartridge
|
(1) RBC2 |
|
 |
 |
|
Physical |
|
Maximum height dimensions
|
6.50 inches ( 16.51 cm) |
|
 |
|
Maximum width dimensions
|
3.60 inches ( 9.14 cm) |
|
 |
|
Maximum depth dimensions
|
11.20 inches ( 28.45 cm) |
|
 |
|
Net weight |
12.50 lbs ( 5.68 kg) |
|
 |
|
Shipping Weight |
14.00 lbs ( 6.36 kg) |
|
 |
|
Shipping Height |
10.35 inches ( 26.29 cm) |
|
 |
|
Shipping Width |
6.89 inches ( 17.50 cm) |
|
 |
|
Shipping Depth |
14.06 inches ( 35.71 cm) |
|
 |
|
Color |
Beige |
|
 |
 |
|
Environmental |
|
Operating Environment
|
0 - 40 °C (32 - 104°F) |
|
 |
|
Operating Relative Humidity
|
0 - 95% |
|
 |
|
Operating Elevation
|
0-10000 feet (0-3000 m) |
|
 |
|
Storage Temperature
|
-15 - 45 °C (5 - 113°F) |
|
 |
|
Storage Relative Humidity
|
0 - 95% Non-condensing |
|
 |
|
Storage Elevation
|
0-50000 feet (0-15000 m) |
|
 |
|
Audible noise at 1 meter from
surface of unit |
45 dBA |
|
 |
|
Online thermal dissipation
|
20 BTU/hr |
|
 |
 |
|
Conformance |
|
Approvals |
FCC Part 15 Class B, Industry Canada, UL 1778, cUL Listed |
|
 |
|
Standard warranty
|
2 years repair or replace |
|
 |
|
|
 |
 |
|
** The time to recharge to 90% of full
battery capacity following a discharge to shutdown using a
load rated for 1/2 the full load rating of the UPS. |
|