Product
Overview
|
| |
Description |
APC Back-UPS Pro, 1000VA/670W, Input
120V/ Output 120V, Interface
Port DB-9 RS-232 |
|
 |
| |
Features |
Audible Alarms, Automatic Voltage
Regulation (AVR), Building wiring fault
indicator, Hot Swap Batteries, Intelligent
Battery Management, Internet FAX - modem -
DSL surge protection, Lightning and Surge
Protection, Network Data Line Surge
Protection, Overload Indicator, Replace Batt
Indicator, Resettable circuit breaker, User
Replaceable batteries |
|
 |
| |
Includes |
User Manual |
|
 |
 |
 |
| Documentation |
| |
User Manual
& Installation Guides |
APC
Safety Guide (120V)
Back-UPS
Pro 1000/1100/1400 (120V)
Back-UPS
Pro 280/420/650/1000/1400 (120V)
|
|
 |
 |
Communications
& Management
|
| |
Interface
port |
DB-9 RS-232 |
|
 |
| |
Control panel |
LED status display with On Line : On
Battery : Replace Battery and Overload
indicators |
|
 |
| |
Audible alarm |
Alarm when on battery : distinctive low
battery alarm : overload continuous tone
alarm |
|
 |
 |
| Output |
| |
Output power
capacity |
1,000 VA |
|
 |
| |
Output power
capacity |
670 Watts |
|
 |
| |
Nominal
output voltage |
120 V |
|
 |
| |
Waveform type |
Stepped approximation to a sinewave |
|
 |
| |
Output
Connections |
| (6)NEMA
5-15R |
 |
|
|
 |
 |
Input
|
| |
Nominal input
voltage |
120 V |
|
 |
| |
Input
frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
|
 |
| |
Input
Connection Type |
| NEMA
5-15P |
 |
|
|
 |
| |
Cord Length |
6 feet |
|
 |
| |
Input voltage
range for main operations |
88 - 148 V |
|
 |
 |
Surge
Protection and Filtering
|
| |
Surge energy
rating |
320 joules |
|
 |
| |
Filtering |
Full time multi-pole noise filtering :
0.3% IEEE surge let-through : zero clamping
response time : meets UL 1449 |
|
 |
| |
Dataline
protection |
RJ-45 Modem/Fax/DSL/10-100 Base-T
protection |
|
 |
 |
| Runtime |
| |
Typical
backup time
at half load |
18.6 minutes (335 Watts) |
|
 |
| |
Typical
backup time
at full load |
6.6 minutes (670 Watts) |
|
 |
| |
Runtime Chart |
Back-UPS
Pro |
|
 |
 |
| Batteries |
| |
Battery type |
Maintenance-free sealed Lead-Acid battery
with suspended electrolyte : leakproof |
|
 |
| |
Typical
recharge time ** |
3 hour(s) |
|
 |
| |
Replacement
battery cartridge |
(1) RBC6 |
|
 |
 |
| Physical |
| |
Maximum
height dimensions |
8.50 inches ( 21.59 cm) |
|
 |
| |
Maximum width
dimensions |
6.70 inches ( 17.02 cm) |
|
 |
| |
Maximum depth
dimensions |
17.30 inches ( 43.94 cm) |
|
 |
| |
Net weight |
42.60 lbs ( 19.36 kg) |
|
 |
| |
Shipping
Weight |
47.10 lbs ( 21.41 kg) |
|
 |
| |
Shipping
Height |
14.00 inches ( 35.56 cm) |
|
 |
| |
Shipping
Width |
12.50 inches ( 31.75 cm) |
|
 |
| |
Shipping
Depth |
23.00 inches ( 58.42 cm) |
|
 |
| |
Color |
Beige |
|
 |
 |
| Environmental |
| |
Operating
Environment |
0 - 40 °C (32 - 104°F) |
|
 |
| |
Operating
Relative Humidity |
0 - 95% |
|
 |
| |
Operating
Elevation |
0-10000 feet (0-3000 m) |
|
 |
| |
Storage
Temperature |
-15 - 45 °C (5 - 113°F) |
|
 |
| |
Storage
Relative Humidity |
0 - 95% Non-condensing |
|
 |
| |
Storage
Elevation |
0-50000 feet (0-15000 m) |
|
 |
| |
Audible noise
at 1 meter from surface of unit |
50 dBA |
|
 |
 |
| Conformance |
| |
Approvals |
CSA, FCC Part 15 Class B, FCC Part 68, UL
1778 |
|
 |
| |
Standard
warranty |
2 years repair or replace |
|
 |
| |
Equipment
protection policy |
Lifetime
: $150000 |
|
 |
 |
|
** The time to recharge to
90% of full battery capacity following a
discharge to shutdown using a load rated for
1/2 the full load rating of the UPS.
|
| |