Product
Overview
|
| |
Description |
APC Back-UPS Pro, 280VA/180W, Input
120V/ Output 120V, Interface
Port DB-9 RS-232 |
|
 |
| |
Features |
Addl Surge Protected Outlets, Audible
Alarms, ERROR: No Translation Found,
Automatic Voltage Regulation (AVR),
BlockSafe Outlets/Cord Extensions, Building
wiring fault indicator, Easy Overload
Recovery, Hot Swap Batteries, Intelligent
Battery Management, Internet FAX - modem -
DSL surge protection, Lightning and Surge
Protection, Network Data Line Surge
Protection, Overload Indicator, Replace Batt
Indicator, Software, User Replaceable
batteries |
|
 |
| |
Includes |
User Manual, Velcro Cord Management
Straps, Smart UPS signalling RS-232 cable,
CD with software |
|
 |
| |
UPC Code |
731304009641 |
|
 |
 |
| Options |
| |
Optional
Batteries |
Click here to view optional
Batteries. |
|
 |
| |
Optional
Service |
Click here to view optional
Service. |
|
 |
| |
Optional
Software |
Click here to view optional
Software. |
|
 |
 |
| Documentation |
| |
User Manual
& Installation Guides |
APC
Safety Guide (120V)
Back-UPS
Pro 280/420/650S (120V)
|
|
 |
 |
Communications
& Management
|
| |
Interface
port |
DB-9 RS-232 |
|
 |
| |
Control panel |
LED status display with On Line : On
Battery : Replace Battery and Overload
indicators |
|
 |
| |
Audible alarm |
Alarm when on battery : distinctive low
battery alarm : overload continuous tone
alarm |
|
 |
 |
| Output |
| |
Output power
capacity |
280 VA |
|
 |
| |
Output power
capacity |
180 Watts |
|
 |
| |
Nominal
output voltage |
120 V |
|
 |
| |
Waveform type |
Stepped approximation to a sinewave |
|
 |
| |
Output
Connections |
| (2)NEMA
5-15R |
 |
| (1)NEMA
5-15R (Surge) |
|
|
|
 |
 |
Input
|
| |
Nominal input
voltage |
120 V |
|
 |
| |
Input
frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
|
 |
| |
Input
Connection Type |
| NEMA
5-15P |
 |
|
|
 |
| |
Cord Length |
6 feet |
|
 |
| |
Input voltage
range for main operations |
82 - 147 V |
|
 |
| |
Input voltage
adjustable range for main operations |
78 - 152 V |
|
 |
 |
Surge
Protection and Filtering
|
| |
Surge energy
rating |
480 joules |
|
 |
| |
Filtering |
Full time multi-pole noise filtering : 5%
IEEE surge let-through : zero clamping
response time : meets UL 1449 |
|
 |
| |
Dataline
protection |
RJ-45 Modem/Fax/DSL/10-100 Base-T
protection |
|
 |
 |
| Runtime |
| |
Typical
backup time
at half load |
23.1 minutes (90 Watts) |
|
 |
| |
Typical
backup time
at full load |
6.7 minutes (180 Watts) |
|
 |
| |
Runtime Chart |
Back-UPS
Pro |
|
 |
 |
| Batteries |
| |
Battery type |
Maintenance-free sealed Lead-Acid battery
with suspended electrolyte : leakproof |
|
 |
| |
Typical
recharge time ** |
7 hour(s) |
|
 |
| |
Replacement
battery cartridge |
(1) RBC2 |
|
 |
 |
| Physical |
| |
Maximum
height dimensions |
5.90 inches ( 14.99 cm) |
|
 |
| |
Maximum width
dimensions |
3.40 inches ( 8.64 cm) |
|
 |
| |
Maximum depth
dimensions |
13.30 inches ( 33.78 cm) |
|
 |
| |
Net weight |
16.60 lbs ( 7.55 kg) |
|
 |
| |
Shipping
Weight |
20.40 lbs ( 9.27 kg) |
|
 |
| |
Shipping
Height |
10.60 inches ( 26.92 cm) |
|
 |
| |
Shipping
Width |
7.80 inches ( 19.81 cm) |
|
 |
| |
Shipping
Depth |
18.40 inches ( 46.74 cm) |
|
 |
| |
Color |
Beige |
|
 |
 |
| Environmental |
| |
Operating
Environment |
0 - 40 °C (32 - 104°F) |
|
 |
| |
Operating
Relative Humidity |
0 - 95% |
|
 |
| |
Operating
Elevation |
0-10000 feet (0-3000 m) |
|
 |
| |
Storage
Temperature |
-15 - 45 °C (5 - 113°F) |
|
 |
| |
Storage
Relative Humidity |
0 - 95% Non-condensing |
|
 |
| |
Storage
Elevation |
0-50000 feet (0-15000 m) |
|
 |
| |
Audible noise
at 1 meter from surface of unit |
45 dBA |
|
 |
 |
| Conformance |
| |
Approvals |
CSA, FCC Part 15 Class B, FCC Part 68, UL
1778 |
|
 |
| |
Standard
warranty |
2 years repair or replace |
|
 |
| |
Equipment
protection policy |
Lifetime
: $75000 |
|
 |
 |
|
** The time to recharge to
90% of full battery capacity following a
discharge to shutdown using a load rated for
1/2 the full load rating of the UPS.
|
| |